Skip to main content
← Back to Home

0.2mm Via Current Calculator

3 Vias | Small Via | IPC-2221 trace formula (approximation)

Calculated Result

For 0.2mm (8 mil) via with 25µm plating and 3 via(s):

4.37A total

(1.46A per via)

Via Parameters

MOD: VIA_CUR_V1
mm
µm
mm
°C
Via Current Analysis

Capacity Check

Total Capacity
4.37A

3 vias × 1.46 A each

Current / Via
1.457A
Resistance / Via
1.592mΩ
Total Resistance
0.531mΩ
Voltage Drop
2.319mV
Via Cross-Section (Not to Scale) — 3 vias0.2mm25µm

Design Recommendations

Via Sizing Tips

  • •Standard via (0.2mm) carries 1.46A per via
  • •Cross-sectional area: 17,671 µm²
  • •For higher current: use larger vias or increase plating thickness

Via Array Guidelines

  • •Parallel vias share current equally when properly connected
  • •Place vias in grid pattern near power pins for best distribution
  • •Consider thermal vias for heat dissipation from power components

Understanding 0.2mm Via Current Capacity

A 0.2mm (8 mil) plated through hole (PTH) via with standard 25µm copper plating is estimated to carry about 1.46A per via with the IPC-2221 trace-current formula applied to the barrel copper. When using 3 parallel via(s), the total current capacity increases to 4.37A, making this configuration suitable for power distribution networks.

Key Parameters for 0.2mm Via

  • Hole Diameter: 0.2mm (8 mil) - small via category
  • Plating Thickness: 25µm (standard electroplated copper)
  • Board Thickness: 1.6mm (via barrel length)
  • Temperature Rise: 10°C (the default used on this page)
  • Cross-Section Area: 17,671 µm² per via
  • Resistance: 1.592 mΩ per via

Why Use 3 Parallel Via(s)?

Using 3 parallel 0.2mm vias divides the total current load, reducing thermal stress on each individual via and providing redundancy. With 3 vias, the total resistance drops to 0.531 mΩ (compared to 1.592 mΩ for a single via). At the same load current the voltage drop is 3 times lower than with one via; at this page's maximum current (4.37A) the drop is 2.32 mV, the same as a single via at its own limit, because capacity scales with the via count too.

How the Via Current Is Estimated

This page reuses the IPC-2221 trace-current formula I = 0.048 × ΔT^0.44 × A^0.725 (I in A, ΔT in °C, A in mil²), with A taken as the copper ring of the plated barrel. It is an approximation: the formula was fitted to planar traces, not via barrels, so treat the result as a screening estimate and confirm critical designs with your fabricator's plating data and a thermal check. For a 0.2mm hole with 25µm plating the copper ring is 17,671 µm², which gives 1.46A per via at a 10°C rise.

Typical Applications for 0.2mm Via with 4.37A Capacity

•DC-DC converter layer transitions
•Battery charging circuits
•Motor controller power stages
•Power amplifier supply rails

Frequently Asked Questions

Can I use fewer than 3 via(s) for 4.37A?

Reducing the number of vias raises the temperature rise above 10°C for the same current, because the same current flows through less copper. Whether a higher rise is acceptable depends on your board's thermal limit; use the calculator above to see the estimate for other via counts.

Should I use filled or hollow vias for 0.2mm?

For small vias like 0.2mm, hollow vias with multiple parallel vias (as shown here with 3 vias) are typically more cost-effective than filled vias. Filled vias provide better thermal performance but at higher manufacturing cost.

What spacing should I use between 3 parallel vias?

The minimum spacing depends on your fabricator's drill-to-drill, annular-ring and pad-size rules, so check their capability sheet. This calculator does not model current sharing between vias; it assumes the vias are identical and carry equal current.

Related Via Current Calculations

0.2 mm × 3 vias compared with other hole sizes

Estimates use 25 µm plating, a 1.6 mm board and 10 °C rise, from the same function as the calculator above.

What it takes to carry 4.4 A
HolePer via (A)Vias neededR per via (mΩ)
0.2 mm1.4641.59
0.3 mm1.9031.10
0.4 mm2.3120.84
0.5 mm2.6920.68

Here 3 parallel vias give a combined resistance of 0.53 mΩ and drop 2.3 mV at the estimated limit. The estimate treats the barrel alone: connecting traces and planes usually limit the real path first. Open the full via calculator. To size the connecting trace, open the trace width calculator prefilled with 4 A (this via set's estimated limit rounded down, not your design current; assumes 1 oz external).

Complete Your PCB Design

After calculating via current for 0.2mm with 3 via(s), use our other free tools to complete your PCB design. Calculate trace widths for power traces, or analyze impedance for high-speed signals.