Skip to main content
← Back to Home

0.5mm Via Current Calculator

5 Vias | Power Via | IPC-2221 trace formula (approximation)

Calculated Result

For 0.5mm (20 mil) via with 25µm plating and 5 via(s):

13.47A total

(2.69A per via)

Via Parameters

MOD: VIA_CUR_V1
mm
µm
mm
°C
Via Current Analysis

Capacity Check

Total Capacity
13.47A

5 vias × 2.69 A each

Current / Via
2.693A
Resistance / Via
0.682mΩ
Total Resistance
0.136mΩ
Voltage Drop
1.837mV
Via Cross-Section (Not to Scale) — 5 vias0.5mm25µm

Design Recommendations

Via Sizing Tips

  • •Standard via (0.5mm) carries 2.69A per via
  • •Cross-sectional area: 41,233 µm²
  • •For higher current: use larger vias or increase plating thickness

Via Array Guidelines

  • •Parallel vias share current equally when properly connected
  • •Place vias in grid pattern near power pins for best distribution
  • •Consider thermal vias for heat dissipation from power components

Understanding 0.5mm Via Current Capacity

A 0.5mm (20 mil) plated through hole (PTH) via with standard 25µm copper plating is estimated to carry about 2.69A per via with the IPC-2221 trace-current formula applied to the barrel copper. When using 5 parallel via(s), the total current capacity increases to 13.47A, making this configuration suitable for high-current power applications.

Key Parameters for 0.5mm Via

  • Hole Diameter: 0.5mm (20 mil) - power via category
  • Plating Thickness: 25µm (standard electroplated copper)
  • Board Thickness: 1.6mm (via barrel length)
  • Temperature Rise: 10°C (the default used on this page)
  • Cross-Section Area: 41,233 µm² per via
  • Resistance: 0.682 mΩ per via

Why Use 5 Parallel Via(s)?

Using 5 parallel 0.5mm vias divides the total current load, reducing thermal stress on each individual via and providing redundancy. With 5 vias, the total resistance drops to 0.136 mΩ (compared to 0.682 mΩ for a single via). At the same load current the voltage drop is 5 times lower than with one via; at this page's maximum current (13.47A) the drop is 1.84 mV, the same as a single via at its own limit, because capacity scales with the via count too.

How the Via Current Is Estimated

This page reuses the IPC-2221 trace-current formula I = 0.048 × ΔT^0.44 × A^0.725 (I in A, ΔT in °C, A in mil²), with A taken as the copper ring of the plated barrel. It is an approximation: the formula was fitted to planar traces, not via barrels, so treat the result as a screening estimate and confirm critical designs with your fabricator's plating data and a thermal check. For a 0.5mm hole with 25µm plating the copper ring is 41,233 µm², which gives 2.69A per via at a 10°C rise.

Typical Applications for 0.5mm Via with 13.47A Capacity

•High-power MOSFET/IGBT connections
•Thermal via arrays under power components
•Power inverter main bus
•EV/automotive power distribution

Frequently Asked Questions

Can I use fewer than 5 via(s) for 13.47A?

Reducing the number of vias raises the temperature rise above 10°C for the same current, because the same current flows through less copper. Whether a higher rise is acceptable depends on your board's thermal limit; use the calculator above to see the estimate for other via counts.

Should I use filled or hollow vias for 0.5mm?

For power vias like 0.5mm, hollow vias with multiple parallel vias (as shown here with 5 vias) are typically more cost-effective than filled vias. Filled vias provide better thermal performance but at higher manufacturing cost.

What spacing should I use between 5 parallel vias?

The minimum spacing depends on your fabricator's drill-to-drill, annular-ring and pad-size rules, so check their capability sheet. This calculator does not model current sharing between vias; it assumes the vias are identical and carry equal current.

Related Via Current Calculations

0.5 mm × 5 vias compared with other hole sizes

Estimates use 25 µm plating, a 1.6 mm board and 10 °C rise, from the same function as the calculator above.

What it takes to carry 13.5 A
HolePer via (A)Vias neededR per via (mΩ)
0.2 mm1.46101.59
0.3 mm1.9081.10
0.4 mm2.3160.84
0.5 mm2.6950.68

Here 5 parallel vias give a combined resistance of 0.14 mΩ and drop 1.8 mV at the estimated limit. The estimate treats the barrel alone: connecting traces and planes usually limit the real path first. Open the full via calculator. To size the connecting trace, open the trace width calculator prefilled with 13 A (this via set's estimated limit rounded down, not your design current; assumes 1 oz external).

Complete Your PCB Design